- Universal III
509-7X Series Transmitter using 409-1000 Series Electronics
The Universal III provides advanced internal Admittance circuitry that enables the system to ignore significant process coating deposits on the RF sensors with 4-20mA HART protocol for configuration and signal outputs suitable for Class I, Div. 1, hazardous areas.
- Smart Check Well
509-7X Series Transmitter using 409-1000 Series Electronics
The Smart CheckWell provides capability of water well measurements to 800 ft. depths. Internal Admittance circuitry provides advanced internal Admittance circuitry that enables the system to ignore significant process coating deposits on sensors with 4-20mA HART protocol for configuration and signal outputs suitable for Class I, Div. 1, hazardous areas.
- RCT RF
RCT 10, 11, 12, &, 13 Series Transmitter with HART Protocol using 409-T Electronics
The RCT Series provides advanced internal Admittance circuitry that enables the system to ignore significant process coating deposits on sensors with 4-20mA HART protocol for configuration and signal outputs suitable for Class I, Div. 1 & Zone 0, Zone 1 hazardous areas.
- Universal Lite
509-1X Series Transmitter using 409-1400 Series Electronics
The Universal Lite provides cost effective measurements on liquid applications that do not leave a significant process coating deposits on sensors. A 4-20 mA HART output with optional local display configuration allows for full system set-up without the need for costly HART Communicators.
- True Level
509-8X Series Transmitter using 409-2000 Series Electronics
The True Level III provides the ability to provide accurate measurements on homogeneous (blended) liquids that may have changing process material compositions without the need for calibration or recalibration due to process material changes. 4-20mA HART protocol for configuration and signal outputs suitable for Class I, Div. 1 hazardous areas.
- Drop-In-Displacer²
509-7X Series Transmitter with HART Protocol using 409-1000 Series Electronics
The Displacer² provides the ability to replace maintenance intensive electrical or mechanical displacer assemblies with alternate technologies such as RF Admittance that have no moving parts and require no periodic or routine maintenance.
- SLT II
509-5X Series Transmitter using 409-1200 Series Electronics
The SLT II Series provides advanced internal Admittance circuitry that enables the system to ignore significant process coating deposits on the RF sensors with 4-20mA R100/200 & Honeywell DE protocol for configuration and signal outputs suitable for Class I, Div. 1 hazardous areas.
- Universal II
508-4X Series Transmitter using 408-8200 Series Electronics
The Universal II Series RF Admittance system provides advanced internal Admittance circuitry that enables the system to ignore significant process coating deposits on the RF sensors with 4-20mA analog output, manual adjustments for calibration, suitable for Class I, Div. 1 hazardous areas.
- Desalter
509-76-718 Series Transmitter with HART Protocol using 409-1000 Series Electronics
The Drexelbrook Desalter Interface Transmitters accurately measure the electrical interface in the emulsion, even in up set conditions. The transmitter allows operators to keep this electrical interface close (but not too close) to the grids, to maximize separation efficiency.
- Water Bottoms - RF Level Transmitter
Drexelbrook's Interface transmitter can accurately measure the hydrocarbon/water (BS&W) interface location at the bottom of fuel storage tanks.
|
|
|
|