Skip to content

Universal V Level System

The Universal V™ Series is the fifth generation RF continuous system built on Drexelbrook’s 50 years of experience in level measurement. The product is backward compatible with the industry standard Universal III™, Universal Lite™, Universal II™, RCT™ Series and Universal IV and is the ideal solution for a wide array of applications
Universal IV

The Universal V Series offers worldwide hazardous area approvals including FM, FMc, ATEX & IECEx, standard display/keypad, autoranging capabilities and improved firmware and software for a more reliable measurement.

Pro Model
The Universal V™ Pro model integrates the RF Admittance technology pioneered by Drexelbrook with the versatility of Cote-Shield™ technology that ignores coatings on the probe and measurement span of 1" to 800'. The Pro is compatible with a vast array of applications: conductive, insulating, and heavy or light coating.

Lite Model
The Universal V™ Lite model is the entry level RF Capacitance measurement system without Cote-Shield™ capabilities. Lite models can be used in non-coating conductive liquids and insulated coating applications where Cote-Shield™ is not required. In addition, the Lite model offers a measurement range up to 20' typically.

The Universal V level system is also available in a model specially designed for water well level monitoring.

Key Features
Easy one-time calibration, configure it once and go
Low cost of ownership, no maintenance and no moving parts to wear out
Immuine to tank obstructions such as nozzles, ladders, pipes and agitators
Hazardous location approvals, Intrinsic Safety (IS) and Explosion Proof for Class I, Div I installations
2-wire, 4-20mA loop transmitter with the widely accepted digital HART protocol
Measurement span as short as 1” (25mm) to 800 ft (244m), no dead zone or blocked measurement areas

Product Type
Liquid level sensor, Granular level sensor, Slurry level sensor, Interface level sensor, Continuous level sensor, Tank level indicator, Water level sensor, Water level switch, Level gauge, Level system, Level transmitter

Request more information to see how we can help you with a level system that suits your need.

  • Documentation +

  • Video +

    ProductVideoMessage

  • Application Notes / How To Guides +

    • Measuring Level of Wort in Brew Kettle

      Drexelbrook offer point level solutions for measuring level of wort in brew kettles. The nature of the application, hot, steamy, boiling surface, make many level technologies unsuitable for measuring level of wort in a brew kettle.

    • Non-Contact Sensing with RF Proximity Level System

      Accurate and versatile level measurement for difficult applications such as bed depth on conveyors, centrifuge “cake” level, and catenary control.

    • Foam Trending

      Drexelbrook offers an accurate and reliable foam level measurement solution for the beer and wine industry.

    • Level Measurement with Beer Foam

      There are two possible measurements available using RF probes when beer foam is involved.

    • Over-Boil Issues in the Brewing Industry

      A Major North American Brewery discovers a solution to Kettle Over-Boil that has several monetary benefits to plant operations.

    • Filler Bowl Applications

      Learn how to provide accurate level control and ignore foams in filler bowl applications with Drexelbrook level measurement technologies.

    • Measuring Level of Condensed Milk in Evaporator

      Monitor the level of milk in the pipe and control the pump speed to avoid running dry causing cavitation and possibly damaging the pump.

    • Molasses Inventory in Large Storage Tanks

      Measurement of this large volume commodity presents several unique problems. Drexelbrook offer a solution.

    • Alternative to Displacer Level Measurement

      Avoid inaccurate results and high maintenance. Drexelbrook offers a cost effective alternative to displacer level measurements for refinery and petrochemical applications.

    • Level Measurement Solutions for the Petrochemical Industries

      Drexelbrook offer reliable and cost effective level measurement solutions to the petrochemical industries.

    • Oil Separation Assisted by Drexelbrook

      The first criterion for accurate interface control within the oil industry is good separation. Learn how to control separation...

    • Liquid Natural Gas Separation in Fractionation Plants

      The Drexelbrook RF Admittance technology addresses all problems of mechanical displacers with a technology that measures Interface level independent of specific gravity or density and has no moving parts to wear out or break.

    • Water Bottoms

      Drexelbrook's Interface transmitter can accurately measure the hydrocarbon/water (BS&W) interface location at the bottom of fuel storage tanks.

    • Cost Effective Alternative to Displacer Level Measurement

      Displacer’s often provide inaccurate results combined with High Maintenance. However, the Drexelbrook RF Admittance technology...

    • Coker Drum Level in Oil Refineries

      A coker drum involves processing heavy oils for up to 16 hours at 800 degrees Fahrenheit and 65 psig. 800 degrees is too high for many level technologies, but the Drexelbrook DR7000 radar level transmitter...

    • De-Ionized Water Indication and Control

      Drexelbrook RF systems will accurately, reliably and repeatedly make DI Water measurements without “drift” by the correct selection of 3A approved Teflon covered sanitary sensors and electronic module selection.

    • Foam Measurement in PVC Suspension Reactors

      An RF Admittance level transmitter that utilizes a model 700-0002-024 sensing element is ideal for handling the measurement of PVC Foam.

    • Seal Oil Level Indication for Gas Compressors

      Drexelbrook offers a solution to easy, maintenance free seal oil level indication for gas compressors.

    • Level Measurement Solutions for Paper Mills

      Density changes og hot oil make pressure and differential pressure systems inaccurate and unreliable. An RF Admittance system could be the solution.

    • Thermic (Hot) Oil Dryers in Paper Mills

      Paper drying is the most temperature-critical and energy capitalintensive aspect of papermaking. This is how you....

    • Hydraulic Oil Level Measurement

      Hydraulic and Lube Oil Reservoir level measurement is critical to prolong roller bearing and carriage life in paper production. Drexelbrook offers a solution.

    • Critical Level Measurement for Hydraulic Oil

      The level measurement of the hydraulic oil reservoir is critical to peak performance of the paper line. Drexelbrook offers a solution.

    • Lube Oil Contaminationm Monitor

      Large fabricating machines typically have ambient air or water getting into the system due to leaks. Drexelbrook offers a solution.

    • Ink Level in Reservoir of Industrial Printing Press

      Ink reservoirs are small with measuring spans of only several inches. Using floats for level measurement has proved to be unreliable. The Universal RF level transmitter...

    • Thickness Measurement of Drywall

      Manual measurement is time-consuming and shutting down the line reduces output. An RF Admittance level transmitter offers quick and easy level meassurement of wet gypsum.

    • Electrostatic Hazards in Granular Bins

      When assessing the safety of a storage tank, which contains an ignitable, insulating granular, or one that produces an ignitable dust or vapor, there are two sources of ignition to evaluate.

    • Liquid Interface Measurements

      RF Admittance has a unique inherent ability to separate the electrical (Radio Frequency) current flow between a conductive and non-conductive liquid.